Yaskawa A1000 Feature Highlights

  • Ratings: 3/4 to 1000 Hp at 460VAC ; 1/2 to 175 Hp at 230VAC
  • Closed or open loop vector control for outstanding regulation, torque production, and position control capability
  • Continuous Auto-tuning optimizes performance by compensating for changes in motor temperature
  • High Frequency Injection enables high precision open loop control of Interior Permanent Magnet Motors
  • Fast acting current and voltage limiters help achieve continuous drive operation during periods of excessive demand
  • High Slip Braking reduces installation cost and the need for dynamic braking resistors
  • Communication options for all major industrial networks provides high speed control and monitoring, reducing installation cost
  • DriveWizard computer software and Application Sets for easy configuration
  • Auxiliary Control Power Unit maximizes production time and efficiency by maintaining network communication while main power is removed
  • Embedded Safe Torque Off minimizes downtime for applications requiring occasional intervention (SIL CL2, PLd, Category 3)
  • Embedded function blocks, programmable with DriveWorks EZ, provide additional application flexibility and the opportunity to eliminate separate controllers
  • USB Copy Unit and Keypad configuration storage provide speed and convenience for duplicate configuration of multiple drives
  • Removable terminal board with configuration storage provides convenience of configuration backup
  • Made with RoHS compliant materials
  • Integrated DC Reactor (standard on 30HP and larger) for input harmonic reduction
  • Kinetic Energy Braking allows drive to remain in control during momentary power losses


  • Item
    Specification
    Overload Capacity150% for 60 sec. (HD), 120% for 60 sec. (ND)
    Output Frequency0~400 Hz (higher frequencies available with custom software)
    Control MethodsOpen and Closed Loop Current Vector;
    Open and Closed Loop V/f
    Motor TypesInduction
    Surface Permanent Magnet (excluding 600V class)
    Interior Permanent Magnet (excluding 600V class)
    Protective DesignIP20/NEMA1
    Ambient Operating Temperature-10 to +50°C (Chassis Installation)
    -10 to +40°C (Chassis with zero side clearance, or Type 1)
    Braking TransistorStandard through 50HP (ND), 40HP (HD)
    Global CertificationUL, CSA, CE, C-Tick, RoHS
    Standard I/O(8) multi-function digital inputs (24Vdc)
    (3) multi-function analog inputs (0 +/- 10 VDC, 4-20mA)
    (1) multi-function pulse inputs
    (1) fault relay output (form C)
    (3) multi-function relay outputs (form A)
    (2) multi-function analog output (0 +/- 10 VDC,4-20mA)
    (1) multi-function pulse output
    I/O Expansion3 Analog Inputs -10 to +10V, 13 bit plus sign, 4 to 20mA
    16 Digital Inputs (+24V for BCD speed reference)
    2 Analog Outputs (-10 to +10V, 11 bit magnitude)
    8 Digital Outputs (6 transistor, 2 relay)
    FeedbackIncremental
    Absolute (Stegmann, Heidenhain EnDat, Resolver)
    Network CommunicationBuilt-in: Modbus RTU, RS-422/485, 115 kbps
    Optional: EtherNet IP, DeviceNet, Modbus TCP/IP, PROFINET, PROFIBUS-DP, MECHATROLINK-II, CANopen, CC-Link
    Speed Control Range1500:1 Closed Loop Vector (IM and PM Motors)
    200:1 Open Loop Vector (IM Motors)
    100:1 Open Loop Vector (PM Motors)
    Speed Control Accuracy£ 0.02%: Closed Loop Vector; ≤ 0.2%; Open Loop Vector
    Speed Response≥ 60 Hz: Closed Loop Vector; ≥ 10 Hz: Open Loop Vector
    Torque Response≥ 344 Hz: Closed Loop Vector
    Function Block DiagramsUp to 100 connections, 1ms program scan time



    REV DATE: 04/08/2011


    ©2020 SCR Controls, Inc.
    3479 Gribble Rd., Matthews, NC 28104
    PO Box 2368, Indian Trail, NC 28079
    email: info@scrcontrols.com

    By viewing this site you agree with Terms of Use.

    This sight is viewed best viewed with the latest versions of Netscape, Internet Explorer and Chrome.


    A. Manufactured items:
    MELLTRUM (SPECTRUM REPLACEMENT) ES100A ES125A ES150A ES150ARG ES200A ES200ARG ES222 ES2300RG ES2600RG ES2700 2400-8000 2400-8001W 2450-8000W 2450-8001W 2450-8010W 2450-8015W EDDY CURRENT CLUTCH 1235 367 FOCUS 2 FOCUS1 FOCUS 1 REPLACEMENT BOULIGNY MARK ANDY SECO BALDWIN ENKEL CUSTOM AUTOMATION SYSTEMS MULTI DRIVE SYSTEMS ERC REPLACEMENT.